登录 查看组织和合同定价。
选择尺寸
变更视图
关于此项目
线性分子式:
(CH2CF2)n
化学文摘社编号:
NACRES:
NA.23
PubChem Substance ID:
UNSPSC Code:
12162002
MDL number:
vapor pressure
15 mmHg ( 32 °C)
Quality Level
form
beads or pellets
melt index
20-35 g/10 min (230°C/3.8kg)
mol wt
average Mn ~71,000, average Mw ~180,000 by GPC
impact strength
2-4 ft-lb/in. (Izod, ASTM D 256, notched)
dielectric constant
8.0-9.5, 100 Hz (ASTM D 150)
hardness
76-80 (Shore D, ASTM D 2240)
refractive index
n20/D 1.42
ASTM D 3835
6,000-7,500 poise(230 °C) (100 sec-1)(lit.)
transition temp
brittleness temperature -62 °C (ASTM D 746), Tm 155-165 °C
solubility
some polar solvents such as organic esters and amines: soluble
density
1.78 g/mL at 25 °C
SMILES string
FC(F)=C
InChI
1S/C2H2F2/c1-2(3)4/h1H2
InChI key
BQCIDUSAKPWEOX-UHFFFAOYSA-N
Application
涂料、薄膜、滤布、仪器内衬、滤膜、泵零件和内衬以及阀门。
Features and Benefits
结晶方式至少有 3 种,具体情况取决于结晶条件。机械强度高、耐磨性强和电介质强度高。能够抵抗多数化学品、紫外幅射、风化和真菌。
Still not finding the right product?
Explore all of our products under 聚偏二氟乙烯
存储类别
11 - Combustible Solids
wgk
WGK 3
flash_point_f
Not applicable
flash_point_c
Not applicable
ppe
Eyeshields, Gloves, type N95 (US)
商品
Electrospinning technique applications discussed, emphasizing control of nanofibers and assembly into 3D architectures.
S V Ivanov et al.
Klinichna khirurhiia, (7)(7), 37-41 (2012-10-05)
The results of experimental and clinical studies for the comparative evaluation of implants used in herniology of polytetrafluoroethylene (PTFE) and polyvinylidene fluoride (PVDF) are presented. Experimental investigations conducted on 200 mice, which in the anterior abdominal wall mesh prosthesis implanted.
Noriko Kotobuki et al.
Journal of biomedical materials research. Part A, 101(2), 537-546 (2012-08-29)
For tissue engineering and regenerative medicine, stem cells should be effectively cultured in vitro. New thermoresponsive nanocomposite gels (MD-NC gels), consisting of inorganic clay (hectorite) and copolymers composed of hydrophobic 2-methoxyethyl acrylate (MEA) and hydrophilic N,N-dimethylacrylamide (DMAA) units, could be
X S Yi et al.
Water science and technology : a journal of the International Association on Water Pollution Research, 67(3), 477-484 (2012-12-04)
In the present study, nano-sized TiO(2)/Al(2)O(3) modified polyvinylidene fluoride (PVDF) membranes (MM) were fabricated and then utilized for oil/water emulsion separation. The results showed that, compared with PVDF membrane (OM), the contact angle of MM decreased and hydrophilicity increased. The
全球贸易项目编号
| 货号 | GTIN |
|---|---|
| 427152-100G | 04061832104485 |