C85778

邻甲酚酞

Indicator grade, powder

登录 查看组织和合同定价。

选择尺寸

变更视图

关于此项目

经验公式(希尔记法):
C22H18O4
化学文摘社编号:
分子量:
346.38
NACRES:
NA.47
PubChem Substance ID:
UNSPSC Code:
12171500
EC Number:
209-881-8
MDL number:
Beilstein/REAXYS Number:
310554
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助


产品名称

邻甲酚酞, indicator grade

grade

indicator grade

Quality Level

form

powder

technique(s)

titration: suitable

color

beige

pH

8.2-9.8, colorless to red

mp

219-221 °C (lit.)

λmax

381 nm (2nd), 566 nm

ε (extinction coefficient)

≥10000 at 294-300 nm, ≥39000 at 564-570 nm, ≥5000 at 378-384 nm

application(s)

diagnostic assay manufacturing
hematology
histology

storage temp.

room temp

SMILES string

Cc1cc(ccc1O)C2(OC(=O)c3ccccc23)c4ccc(O)c(C)c4

InChI

1S/C22H18O4/c1-13-11-15(7-9-19(13)23)22(16-8-10-20(24)14(2)12-16)18-6-4-3-5-17(18)21(25)26-22/h3-12,23-24H,1-2H3

InChI key

CPBJMKMKNCRKQB-UHFFFAOYSA-N

Application

O -甲酚酞作为钙化介质中的组分用于钙化试验。

Biochem/physiol Actions

o -甲酚酞是一种可逆的 pH 指示剂。反向通路(红紫色至无色)的动力学是缓慢的,因此使其成为检查波纹壁管中流动模式的适当分子。也用于通过 o -甲酚酞络合酮方法比色测定钙含量。在碱性条件 (pH 10-12) 下,钙与 o -甲酚酞结合,形成红色复合物,在 570-575 nm 处有吸光度。


存储类别

11 - Combustible Solids

wgk

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Gloves, type N95 (US)



历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库



Hyunseok Peter Kang et al.
Clinical chemistry, 50(4), 741-746 (2004-02-14)
Gadolinium formulations, which are administered as contrast agents in magnetic resonance imaging examinations, interfere with colorimetric serum calcium determinations. We performed an in vitro study to determine the extent to which three gadolinium formulations-gadodiamide (Omniscan), gadopentetate dimeglumine (Magnevist), and gadoversetamide
Jin-Hyun Kim et al.
PloS one, 14(4), e0215244-e0215244 (2019-04-17)
In the stratum corneum, the intercellular junction made up of cadherin proteins provides the structural integrity of the framework. Ca2+ ions are known to play a key role in maintaining this junction. In this study, we hypothesized that Ca2+ chelation
J E Van Nuwenborg et al.
European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies, 35(4), 297-300 (1997-04-01)
We evaluated bias and inaccuracy of four frequently used routine test systems for serum total calcium, using a candidate reference method based on ion chromatography. The mean biases and 95% confidence intervals that we observed were 0.0 +/- 0.59% for



全球贸易项目编号

货号GTIN
C85778-10G04061833522578