登录 查看组织和合同定价。
选择尺寸
变更视图
关于此项目
经验公式(希尔记法):
C22H36N2O5S
化学文摘社编号:
分子量:
440.60
UNSPSC Code:
12352106
NACRES:
NA.25
PubChem Substance ID:
MDL number:
Beilstein/REAXYS Number:
6182267
Quality Level
assay
≥98.5% (HPLC)
form
powder
SMILES string
CCCCS(=O)(=O)N[C@@H](Cc1ccc(OCCCCC2CCNCC2)cc1)C(O)=O
InChI
1S/C22H36N2O5S/c1-2-3-16-30(27,28)24-21(22(25)26)17-19-7-9-20(10-8-19)29-15-5-4-6-18-11-13-23-14-12-18/h7-10,18,21,23-24H,2-6,11-17H2,1H3,(H,25,26)/t21-/m0/s1
InChI key
COKMIXFXJJXBQG-NRFANRHFSA-N
Gene Information
human ... ITGA2B(3674), ITGB3(3690)
Application
- The efficacy and safety of continuous intravenous tirofiban for acute ischemic stroke patients treated by endovascular therapy: a meta-analysis.:通过meta分析评估急性缺血性卒中患者血管内治疗中连续静脉给药替罗非班的疗效和安全性,具有改善疗效的满意结果(Wang et al., 2024)。
- Initial Experience with a New Self-Expanding Open-Cell Stent System with Antithrombotic Hydrophilic Polymer Coating (pEGASUS Stent) in the Treatment of Wide-Necked Intracranial Aneurysms.:研究报道首次用新的涂层支架系统治疗颅内动脉瘤(有用到替罗非班),结果疗效和安全性增强(Boxberg et al., 2024)。
Packaging
无底玻璃瓶。内含物装在插入的融合锥内。
signalword
Warning
hcodes
Hazard Classifications
Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
target_organs
Respiratory system
存储类别
11 - Combustible Solids
wgk
WGK 3
flash_point_f
Not applicable
flash_point_c
Not applicable
ppe
dust mask type N95 (US), Eyeshields, Gloves
Christoph Kabbasch et al.
Journal of neurointerventional surgery, 11(8), 812-816 (2019-01-25)
Intrasaccular flow disruption represents a new paradigm in endovascular treatment of wide-necked bifurcation aneurysms. To perform a matched case-control study comparing complications and angiographic outcome using the Woven Endobridge (WEB) device and stent-assisted coiling (SAC). Sixty-six patients treated with the
Lukas Goertz et al.
World neurosurgery, 126, e965-e974 (2019-03-17)
Woven Endobridge (WEB) embolization is an approved technique for endovascular treatment of wide-necked and bifurcation aneurysms. However, the WEB has not yet been routinely used for internal carotid artery (ICA) sidewall aneurysms. In this multicenter study, we evaluate the safety
Nohra Chalouhi et al.
Neurosurgery, 71(3), 710-714 (2012-06-07)
Thromboembolic complications are a major concern in stent-assisted coiling of intracranial aneurysms that may be prevented with adequate antiplatelet therapy. To assess the safety and efficacy of tirofiban in stent-assisted coiling. Two protocols were used. In the initial protocol, tirofiban
全球贸易项目编号
| 货号 | GTIN |
|---|---|
| 30165-5MG | 04061832860169 |