跳转至内容
Merck
CN

74480

去甲肾上腺素 盐酸盐

≥98.0% (sum of enantiomers, HPLC)

别名:

L-Arterenol hydrochloride, L-Noradrenaline hydrochloride

登录 查看组织和合同定价。

选择尺寸

变更视图

关于此项目

经验公式(希尔记法):
C8H11NO3 · HCl
化学文摘社编号:
分子量:
205.64
UNSPSC Code:
12352209
NACRES:
NA.77
PubChem Substance ID:
EC Number:
206-345-5
Beilstein/REAXYS Number:
3916100
MDL number:
Assay:
≥98.0% (sum of enantiomers, HPLC)
Form:
crystals
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助


assay

≥98.0% (sum of enantiomers, HPLC)

form

crystals

optical activity

[α]20/D −38.5±5°, c = 2% in H2O

mp

~150 °C (dec.)

storage temp.

2-8°C

SMILES string

Cl[H].NC[C@H](O)c1ccc(O)c(O)c1

InChI

1S/C8H11NO3.ClH/c9-4-8(12)5-1-2-6(10)7(11)3-5;/h1-3,8,10-12H,4,9H2;1H/t8-;/m0./s1

InChI key

FQTFHMSZCSUVEU-QRPNPIFTSA-N

Biochem/physiol Actions

Adrenal medullary stress hormone, mediator of the fight-or-flight response; and the primary neurotransmitter in the post-ganglionic sympathetic (adrenergic) nervous system.


pictograms

Skull and crossbones

signalword

Danger

Hazard Classifications

Acute Tox. 1 Inhalation - Acute Tox. 2 Dermal - Acute Tox. 2 Oral

存储类别

6.1A - Combustible acute toxic Cat. 1 and 2 / very toxic hazardous materials

wgk

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Faceshields, Gloves, type P2 (EN 143) respirator cartridges

法规信息

涉药品监管产品

此项目有



历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库



Giovanni D'Andrea et al.
Scientific reports, 9(1), 6151-6151 (2019-04-18)
Early diagnosis of Parkinson's disease (PD) remains a challenge to date. New evidence highlights the potential clinical value of circulating trace amines (TAs) in early-stage PD and their involvement in disease progression. A new ultra performance chromatography mass spectrometry (UPLC-MS/MS)
Anyue Yin et al.
British journal of pharmacology, 175(16), 3394-3406 (2018-06-03)
Development of combination therapies has received significant interest in recent years. Previously, a two-receptor one-transducer (2R-1T) model was proposed to characterize drug interactions with two receptors that lead to the same phenotypic response through a common transducer pathway. We applied
Jian Wen et al.
The Laryngoscope, 124(5), E188-E193 (2013-10-12)
Noise generated by instruments, such as mastoid or craniotomy drills, may cause hearing damage by reducing the cochlear blood flow (CoBF). This study investigated whether dexmedetomidine can lessen noise-induced hearing loss (NIHL) in a guinea pig model. Animal study using



全球贸易项目编号

货号GTIN
74480-100MG04061832889313
74480-1G04061832889320