跳转至内容
Merck
CN

1233009

USP

依地酸二钠

United States Pharmacopeia (USP) Reference Standard

别名:

乙二胺四乙酸 二钠盐 二水合物, EDTA 二钠盐, EDTA-Na2, 乙二胺四乙酸Na2, 乙二胺四乙酸盐 二钠盐 二水合物, 二钠乙二胺四乙酸盐 二水合物, 依地酸钙钠

登录 查看组织和合同定价。

选择尺寸

变更视图

关于此项目

经验公式(希尔记法):
C10H14N2Na2O8 · 2H2O
化学文摘社编号:
分子量:
372.24
UNSPSC Code:
41116107
NACRES:
NA.24
Beilstein/REAXYS Number:
3900609
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助


grade

pharmaceutical primary standard

API family

edta

manufacturer/tradename

USP

mp

248 °C (dec.) (lit.)

application(s)

pharmaceutical (small molecule)

format

neat

SMILES string

O.O.O.O.[Na+].[Na+].[Na+].[Na+].OC(=O)CN(CCN(CC([O-])=O)CC([O-])=O)CC(O)=O.OC(=O)CN(CCN(CC(O)=O)CC([O-])=O)CC([O-])=O

InChI

1S/C10H16N2O8.2Na.2H2O/c13-7(14)3-11(4-8(15)16)1-2-12(5-9(17)18)6-10(19)20;;;;/h1-6H2,(H,13,14)(H,15,16)(H,17,18)(H,19,20);;;2*1H2/q;2*+1;;/p-2

InChI key

OVBJJZOQPCKUOR-UHFFFAOYSA-L

General description

本品按现行药典规定交付。所有为支持本产品而提供的信息,包括SDS和任何产品信息单均由药典颁发机构制定并发布。如需进一步信息和支持,请访问现行药典网站。

Application

乙二胺四乙酸二钠USP参考标准品,预期用途是USP规定的指定质量测试和检测。也用于USP各论,例如:
  • 乙二胺四乙酸二钠注射液
  • 乙二胺四乙酸二钠复方滴眼液
  • 盐酸左布诺洛尔滴眼液
  • 布地奈德鼻喷雾剂
二价阳离子的螯合剂。 对需要二价阳离子发挥活性的酶,比如金属蛋白酶具有抑制作用。

Analysis Note

这些产品仅供测试和化验使用。它们不适用于人类或动物,也不能用于诊断、治疗或治愈任何类型的疾病。

Other Notes

可能适用相应的销售限制。


pictograms

Health hazardExclamation mark

signalword

Warning

hcodes

Hazard Classifications

Acute Tox. 4 Inhalation - STOT RE 2 Inhalation

target_organs

Respiratory Tract

存储类别

11 - Combustible Solids

flash_point_f

Not applicable

flash_point_c

Not applicable



历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 文件 section.

如需帮助,请联系 客户支持

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库



Pseudothrombocytopenia in a patient receiving romiplostim for immune thrombocytopenic purpura.
Claudio Fozza et al.
Annals of hematology, 93(5), 899-900 (2013-10-02)
Il Joong Park et al.
Archives of pathology & laboratory medicine, 138(8), 1077-1082 (2014-07-31)
The Samsung LABGEO(HC10) Hematology Analyzer (LABGEO(HC10)) is a recently developed automated hematology analyzer that uses impedance technologies. The analyzer provides 18 parameters including 3-part differential at a maximum rate of 80 samples per hour. To evaluate the performance of the
Oivind Midttun et al.
The Journal of nutrition, 144(5), 784-790 (2014-03-22)
Knowledge of stability during sample transportation and changes in biomarker concentrations within person over time are paramount for proper design and interpretation of epidemiologic studies based on a single measurement of biomarker status. Therefore, we investigated stability and intraindividual vs.



全球贸易项目编号

货号GTIN
1233009-200MG04061838722225