grade
anhydrous
product line
Redi-Dri™
assay
(EDTA titration), 99.99% trace metals basis
form
powder
impurities
≤150.0 ppmtrace (metals basis)
mp
1001 °C (lit.)
solubility
H2O: soluble(lit.), ethanol: soluble(lit.)
density
3.55 g/mL at 25 °C (lit.)
cation traces
Al: , B: , Ca: , Co: , Cu: , Fe: , K: , Mg: , Na: , Pb: , Zn:
application(s)
catalysts
SMILES string
Cl[Ni]Cl
InChI
1S/2ClH.Ni/h2*1H;/q;;+2/p-2
InChI key
QMMRZOWCJAIUJA-UHFFFAOYSA-L
General description
We packaged anhydrous Nickel chloride in our innovative Redi Dri™ packaging, which easily can prevent the absorption of moisture. The packaging has distinct features and advantages.
Application
Packaging:
10g in poly bottle with Redi Dri(TM) packaging
Redi Dri(TM) is an innovative packaging system that prevents absorption of environmental moisture by anhydrous & hydroscopic salts during transport and chemical storage without addition of anti-caking agents, preserving the compounds′ quality assured, free-flowing nature. Redi-Dri(TM) also provides a conveniently resealable storage container as a simpler and safer-to-use alternative to one-time-use packaging such as ampules.
While the Redi-Dri(TM) packaging system does offer desiccating properties, opening and closing of the Redi-Dri(TM) bottle is still intended to occur under controlled atmosphere to maintain the highest quality of your MilliporeSigma product
Features and Benefits
- Longer shelf-life as a free-flowing powder without addition of anti-caking agents
- Slower absorption of environmental moisture
- Faster dissolution compared to clumped materials
- No need to chip, chisel, or grind clumped salts.
Packaging
Redi Dri™ is an innovative packaging system that prevents absorption of environmental moisture by anhydrous & hydroscopic salts during transport and chemical storage without addition of anti-caking agents, preserving the compounds′ quality assured, free-flowing nature.
Redi-Dri™ also provides a conveniently resealable storage container as a simpler and safer-to-use alternative to one-time-use packaging such as ampules. While the Redi-Dri(TM) packaging system does offer desiccating properties, opening and closing of the Redi-Dri(TM) bottle is still intended to occur under controlled atmosphere to maintain the highest quality of your MilliporeSigma product
Legal Information
Still not finding the right product?
Explore all of our products under Nickel(II) chloride
signalword
Danger
Hazard Classifications
Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Aquatic Acute 1 - Aquatic Chronic 1 - Carc. 1A Inhalation - Muta. 2 - Repr. 1B - Resp. Sens. 1 - Skin Irrit. 2 - Skin Sens. 1 - STOT RE 1 Inhalation
target_organs
Lungs
Storage Class
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
flash_point_f
Not applicable
flash_point_c
Not applicable
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Global Trade Item Number
| SKU | GTIN |
|---|---|
| 946435-10G | 04065274007250 |